PowerGATE 1DMX Guard
DMX/Art-Net over Powerline Transceiver
PowerGATE 1DMX Guard is a DMX-over-powerline transceiver that sends DMX512 and Art-Net through existing mains cables, so lighting can be controlled without new data wiring or wireless links. One unit transmits to up to 20 receivers on the same circuit over typical distances of up to 300 m.
It is designed for projects where running a separate DMX or Ethernet control cable is difficult, prohibited or simply unwanted, and where wireless control is not reliable enough.
The device receives up to 100 DMX universes via its Ethernet port as Art-Net (or other supported network protocols) and transmits them over the power cable to up to 20 receivers on the same electrical circuit, at distances of up to 300 meters. The same cable that powers the luminaires now also carries the control signal.
PowerGATE 1DMX Guard works both as a transmitter and as a receiver. Its single DMX input and single DMX output let it inject a DMX signal into the power line or output the received data to DMX fixtures at the far end of the line. It supports a wide range of lighting control protocols, including DMX512, RDM, Art-Net, sACN, KiNet and RTTrPL.
The 10/100 Mbps Ethernet port provides remote configuration through a built-in web interface. The fanless design uses the aluminum enclosure itself as the heat sink, so the device runs silently and reliably in continuous operation. It starts up in about 1–2 seconds after power is restored, supports RDM, and offers backup Art-Net control with HTP, LTP, Auto and Priority merge modes.
PowerGATE 1DMX Guard is an indoor device (IP20), installed inside a building
Applications
Heritage and listed buildings
In historic and protected buildings, walls and facades are often part of the architectural heritage, and drilling or running new DMX or Ethernet control cables is not allowed. PowerGATE 1DMX Guard uses the cabling that already powers the luminaires to carry the control signal, so the lighting can be made dynamic and fully controllable without touching the historic fabric of the building.
Retrofit and finished interiors
When construction or finishing work is already complete, adding control cables means opening walls, ceilings or floors. With PowerGATE 1DMX Guard, the existing power line becomes the control line — no new channels, holes or cable routes.
Any site where cabling or wireless is difficult or impossible
Some sites rule out both a new control cable and a radio link: thick stone or concrete walls, metal structures, basements and long corridors block wireless signals, while running new cable is too costly or disruptive. PowerGATE 1DMX Guard uses the power cabling that already feeds the lighting, so control reaches every fixture on the circuit regardless of walls or distance between rooms.
- Powerline transmission: DMX and Art-Net over existing power lines up to 300 m, up to 100 DMX universes
- Point-to-multipoint: one transmitter serves up to 20 receivers on the same electrical circuit
- Transceiver: works as transmitter or receiver — 1 DMX input, 1 DMX output
- Wide protocol support: DMX512, RDM, Art-Net I–IV, sACN, KiNet v1/v2, RTTrPL
- Uses existing wiring: no new control cables, no extra drilling, no noise filters required
- Fanless design: the aluminum enclosure acts as the heat sink — silent, maintenance-free continuous operation
- Compact enclosure: small footprint for installation in tight spaces and junction areas
- Secure power connection: PowerCON TRUE power connector with locking mechanism that prevents accidental disconnection
- Merge modes: HTP, LTP, Auto and Priority for backup Art-Net control
- Fast recovery: ready to work in about 1–2 seconds after power loss
- Non-volatile memory: scenes and configuration profiles are retained without power
- Web configuration: remote setup via built-in web interface over Ethernet
- Isolation: Full galvanic isolation of both DMX/Ethernet interface and the power input (up to 3500 V protection)
- Surge protection: Surge-protected input, withstands up to 305 V AC
- Mechanical
Mounting: Surface mounting (2 through-holes in the enclosure)
Enclosure: Aluminum, acts as heat sink; fanless
Dimensions, mm: 129 (L) x 56 (H) x 118 (W)
Weight: 0.6 kg- Power & Electrical
Supply voltage: 100–270 V AC, 50/60 Hz
Rated current: 0.25 A
Power consumption: max. 5W
Surge protection: Input from 100 to 305 V
Galvanic isolation: Up to 3500 V- Powerline transmission
Distance: Up to 300 m*
DMX universes: Up to 100*
Receivers per circuit: Up to 20*
Noise filters: Not required- Environment
Operating temperature: −40 to +70 °C
Storage temperature: −50 to +80 °C
Relative humidity: Up to 95 %
Ingress protection: IP 20
Installation: indoor only- Compliance & Standards
Compliance: EMC, LVD, CE, RoHS
- Control & Data Connections
Protocols: DMX512, RDM, Art-Net I–IV, sACN, KiNet v1/v2, RTTrPL, PWR DMX
DMX refresh rate: Adjustable, up to 44 Hz
Merge modes: HTP, LTP, Auto, Priority- Inputs / Outputs
DMX: 1 × DMX in (Neutrik XLR 5-pin male), 1 × DMX out (Neutrik XLR 5-pin female)
Ethernet: 1 × 10/100 Mbps, RJ-45 / etherCON
Power input: PowerCON TRUE- Configuration / Indication
Configuration: Web interface
Indicators: LEDs for DMX and Ethernet (Link / Act)- Package Contents
Package contents: PowerGATE 1DMX Guard unit, power cable
Warranty: 5 Years- * Important note on system design
PowerGATE 1DMX Guard transmits data over power lines (PLC), so its performance depends on the electrical network it is connected to. The load on the line and the impedance of the drivers and other devices connected to the same circuit directly affect the achievable distance, the number of universes and the number of receivers.
The figures given above (300 m, 100 DMX universes, 20 receivers) are typical average values. Actual performance depends on the conditions at each site. For this reason, the selection and quantity of devices are always determined locally, based on the current state of the site, the network load and the impedance of connected equipment, with the support of DITRA Solutions specialists.



