PowerGATE 1DMX Shield
IP67 DMX/Art-Net over Powerline Transceiver
PowerGATE 1DMX Shield is a compact, fully sealed transceiver that sends DMX and Art-Net data over existing power lines. Its IP67 aluminum enclosure with sealed cable glands is designed for permanent outdoor use and harsh weather — façades, bridges, parks, waterfronts and other sites where the device is exposed to rain, dust and moisture.
The device receives up to 100 DMX universes via its Ethernet port as Art-Net (or other supported network protocols) and transmits them over the power cable to up to 20 receivers on the same electrical circuit, at distances of up to 300 meters. The same cable that powers the luminaires now also carries the control signal.
PowerGATE 1DMX Shield works both as a transmitter and as a receiver. Its single DMX input and single DMX output let it inject a DMX signal into the power line or output the received data to DMX fixtures at the far end of the line. It supports a wide range of lighting control protocols, including DMX512, RDM, Art-Net, sACN, KiNet and RTTrPL.
All cables — power, DMX input, DMX output and Ethernet — enter the enclosure through individual IP67 cable glands. The 10/100 Mbps Ethernet port provides remote configuration through a built-in web interface. The fanless design uses the aluminum enclosure itself as the heat sink, so the device runs silently and reliably in continuous operation. It starts up in about 1–2 seconds after power is restored, supports RDM, and offers backup Art-Net control with HTP, LTP, Auto and Priority merge modes.
Applications
Outdoor retrofit
When outdoor lighting is already installed and the cable routes are closed, adding control cables means new trenches, conduits or holes. With PowerGATE 1DMX Shield, the existing power line becomes the control line.
Façades, bridges, parks and waterfronts
Long façades, bridges, landscape and park lighting, embankments, theme parks and festival sites — any outdoor object where laying a separate control cable is difficult, expensive or impossible, and where equipment must withstand rain, dust and humidity.
- IP67 protection: fully sealed aluminum enclosure for permanent outdoor installation
- Powerline transmission: DMX and Art-Net over existing power lines up to 300 m, up to 100 DMX universes
- Point-to-multipoint: one transmitter serves up to 20 receivers on the same electrical circuit
- Transceiver: works as transmitter or receiver — 1 DMX input, 1 DMX output
- Wide protocol support: DMX512, RDM, Art-Net I–IV, sACN, KiNet v1/v2, RTTrPL
- Uses existing wiring: no new control cables, no extra drilling, no noise filters required
- Fanless design: the aluminum enclosure acts as the heat sink — silent, maintenance-free continuous operation
- Merge modes: HTP, LTP, Auto and Priority for backup Art-Net control
- Fast recovery: ready to work in about 1–2 seconds after power loss
- Non-volatile memory: scenes and configuration profiles are retained without power
- Web configuration: remote setup via built-in web interface over Ethernet
- Isolation: galvanic isolation up to 3500 V
- Surge protection: surge-protected input from 100 to 305 V
- Mechanical
Mounting: Surface mounting (2 through-holes in the enclosure)
Enclosure: Aluminum, fully sealed, acts as heat sink; fanless
Dimensions,mm: 129 (L) x 56 (H) x 118 (W)
Weight: 0.6 kg- Power & Electrical
Supply voltage: 100–270 V AC, 50/60 Hz
Rated current: 0.25 A
Power consumption: max. 5W
Surge protection: Input from 100 to 305 V
Galvanic isolation: Up to 3500 V- Powerline transmission
Distance: Up to 300 m*
DMX universes: Up to 100*
Receivers per circuit: Up to 20*
Noise filters: Not required- Environment
Operating temperature: −40 to +70 °C
Storage temperature: −50 to +80 °C
Relative humidity: Up to 95 %
Ingress protection: IP 67
Installation: Outdoor- Compliance & Standards
Compliance: EMC, LVD, CE, RoHS
- Control & Data Connections
Protocols: DMX512, RDM, Art-Net I–IV, sACN, KiNet v1/v2, RTTrPL, PWR DMX
DMX refresh rate: Adjustable, up to 44 Hz
Merge modes: HTP, LTP, Auto, Priority- Inputs / Outputs
DMX: 1 × DMX in, 1 × DMX out — via IP67 cable glands
Ethernet: 1 × 10/100 Mbps — via IP67 cable gland
Power input: Via IP67 cable gland- Configuration / Indication
Configuration: Web interface
Indicators: LEDs for DMX and Ethernet (Link / Act)- Package Contents
Package contents: PowerGATE 1DMX Shield unit
Warranty: 5 Years- * Important note on system design
PowerGATE 1DMX Shield transmits data over power lines (PLC), so its performance depends on the electrical network it is connected to. The load on the line and the impedance of the drivers and other devices connected to the same circuit directly affect the achievable distance, the number of universes and the number of receivers.
The figures given above (300 m, 100 DMX universes, 20 receivers) are typical average values. Actual performance depends on the conditions at each site. For this reason, the selection and quantity of devices are always determined locally, based on the current state of the site, the network load and the impedance of connected equipment, with the support of DITRA Solutions specialists.